CETC, an active player in the Belt and Road (B&R) Initiative

Specialty Sensor

CETC is the world leader in manufacturing the most sophisticated sensors in military as well as civilian applications, including weapon systems, manufacturing and machinery, airplanes and aerospace, cars, medicine, robotics, etc. For decades, CETC have designed and fabricated high-reliability, high-performance electrodes for the scientific community. We cater to the customer's needs and are eager to collaborate in designing custom sensors as well.

 

Product Catalogue of Typical Specialty Sensors
MF-901 Metal Film Bridge Igniter
  • Bridge material: NiCr (80%:20%)
  • Bridge resistance: 1Ω~10Ω
  • Resistance accuracy: ±0.1Ω
  • Ignition current: ≤5A (50ms)
  • Ignition time: ≤200μs
  • Bridge area size: 100μm×30μm~200μm×100μm
  • Operating temperature: -55°C~155°C
  • Electrode diameter: 1mm±0.05mm
  • Base size: Φ8mm (customizable)
  • Product packaging: gold wire lead
YZ19, YZ12 Series Pressure Sensitive Core
  • Measuring medium: 316L compatible gas or liquid
  • Operating temperature: -55°C~150°C
  • Power supply: 5V or 1mA (recommended)
  • Range: 0~35kPa, up to 70MPa (customizable)
  • Zero output: 0±2mV
  • Full-scale output: ≥100mV
  • Accuracy: 0.2% FS
  • Temperature drift: ≤ ± 0.03% FS/°C
  • Temperature compensation range: -55°C~150°C
  • Electrical definition:
Lead Color
Black
White
Red
Blue
Lead Function
Supply Positive
Supply Negative
Output Positive
Output Negative
SOI Pressure Sensitive Core
  • Measuring medium: 316L compatible gas or liquid
  • Operating temperature: -55°C~175°C
  • Power supply: 5V or 1mA (recommended)
  • Range: 0~35kPa, up to 70MPa (customizable)
  • Zero output: 0±2mV
  • Full-scale output: ≥100mV
  • Accuracy: 0.2% FS
  • Temperature drift: ≤ ± 0.01% FS/°C
  • Pressure overload: 200% FS
  • Electrical definition:
Lead Color
Black
White
Red
Blue
Lead Function
Supply Positive
Supply Negative
Output Positive
Output Negative
CY-YZ-168 Digital Pressure Sensing Core
  • Measuring Range: 0~35kPa, up to 70MPa (customizable)
  • Operating temperature: -55°C~175°C
  • Input voltage: 7~36VDC
  • Output signal: 1V~5V, I2C signal
  • Accuracy: 0.1% FS
  • Thermal zero drift: ±0.01% FS/°C
  • Thermal sensitivity drift: ±0.01% FS/°C
  • Pressure overload: 150% FS
  • Electrical interface: colored high temperature wire
  • Electrical definition:
Lead Color
Green
Blue
White
Black
Red
Lead Function
Output
IIC Data
IIC Clock
Power Supply
Supply Positive
CY-YB-146 Pressure Sensor
  • Measuring medium: nitrogen, helium, air, exhaust, hydraulic oil, etc.
  • Operating temperature: -60°C~125°C
  • Input voltage: 5V±0.01V
  • Range: 0~50MPa (customizable)
  • Sensitivity: ≥1.5 mV/V
  • Accuracy: 0.2% FS
  • Temperature drift: ≤±0.02% FS/°C
  • Pressure overload: 200% FS
  • Pressure interface: M12×1
  • Electrical interface: rejection line
  • Electrical definition:
Lead Color
Red
Blue
Green
White
Lead Function
Supply Positive
Supply Negative
Output Positive
Output Negative
HS-1A29J Pressure Sensor
  • Measuring medium: gas and liquid medium compatible with stainless steel
  • Operating temperature: -43°C~125°C
  • Input voltage: 15V~30VDC
  • Pressure measuring range: 0~3MPa (customizable)
  • Output signal: 0.5V~5V
  • Accuracy: 0.2% FS
  • Pressure overload: 200% FS
  • Pressure interface: M14×1.5
  • Electrical interface: electrical connector Y4-4ZJ
  • Electrical definition:
Contact
1
2
3
4
Function
Supply Positive
Supply Negative
Output Positive
Output Negative
HS-1D32J Depth Sensor
  • Operating temperature: -25°C~85°C
  • Input voltage: 24V±12VDC
  • Pressure measuring range: 0~200m (customizable)
  • Output signal: 1V~5V
  • Accuracy: 0.5% FS
  • Temperature drift: ≤±0.03% FS/°C
  • Pressure interface: M20×1.5
  • Insulation resistance: ≥1000MΩ (100VDC)
  • Electrical interface: sealed cable outlet
  • Electrical definition:
Lead Color
Red
Black
Blue
Brown
Lead Function
Supply Positive
Supply Negative
Output Positive
Output Negative
CY-YB-100 Intelligent Thin Film Pressure Sensor
  • Measuring medium: air, water, oil medium
  • Operating temperature: -40°C~70°C
  • Input voltage: 24V±2.4V
  • Measuring range: 0~10MPa
  • Zero output: 4mA±0.1mA
  • Full-scale output: 20mA±0.1mA
  • Accuracy: ≤1% FS
  • Pressure overload: 150% FS
  • Pressure interface: NPT 1/2
  • Electrical interface: Y27G-1407ZJBM-B waterproof electrical connector
  • Electrical definition:
Node
1
2
3
4
Function
+24V
Power Loop
CANL
CANH
Node
5
6
7
/
Function
Current Output
SCL
SDA
/
CY-YB-102 Ultra-low Temperature Thin Film Pressure Sensor
  • Measuring medium: gas and liquid media compatible with 17-4PH
  • Operating temperature: -196°C~50°C
  • Excitation: ≤10V
  • Sensitivity: ≥1.2mV/V
  • Range: 0~2MPa, up to 60MPa (customizable)
  • Zero output: ≤1mV
  • Accuracy: 0.2% FS
  • Temperature drift: ≤0.05%/°C
  • Insulation resistance: ≥200MΩ
  • Pressure overload: 200% FS
  • Pressure interface: M12×1
  • Electrical interface: Y4-4ZJ
  • Matching transmitter: split, 1~5V output
  • Electrical definition:
Contact
1
2
3
4
Function
Supply Positive
Supply Negative
Output Positive
Output Negative
CY-YZ-152 Pressure Sensor
  • Measuring medium: gas, liquid, etc.
  • Operating temperature: -55°C~150°C
  • Input voltage: 10VDC±0.1VDC
  • Pressure measuring range: 0.01~0.2MPa
  • Output signal: 0~50mV
  • Accuracy: 0.1% FS
  • Thermal zero drift: ≤0.02% FS/°C
  • Thermal sensitivity drift: ≤0.02% FS/°C
  • Pressure overload: 200% FS
  • Electrical interface: cable outlet
  • Electrical definition:
Lead Color
Red
Black
Yellow
White
Lead Function
Supply Positive
Supply Negative
Output Positive
Output Negative
CY-YZ-169 Pressure Sensor
  • Measuring medium: oil, fuel, air, exhaust, etc.
  • Operating temperature: -40°C~85°C
  • Input voltage: 24V±12VDC
  • Range: 0~8kPa (customizable)
  • Output signal: 0.5~5V
  • Accuracy: 0.3% FS
  • Temperature drift: ≤±0.03% FS/°C
  • Pressure overload: 150% FS
  • Pressure interface: M14×1
  • Electrical interface: connectors
  • Electrical definition:
Node
1
2
3
4
Function
Positive Power
Positive Signal
Ground Signal
Ground Power
CY-YZ-158 Pressure Sensor
  • Measuring medium: oil, fuel, seawater, air, exhaust, etc.
  • Operating temperature: -43°C~125°C
  • Input voltage: 24V±12VDC
  • Range: 0~3MPa (customizable)
  • Output signal: 0.5~5V
  • Accuracy: 0.5% FS
  • Temperature drift: ≤±0.03% FS/°C
  • Pressure overload: 300% FS
  • Pressure interface: M12×1
  • Electrical interface: electrical connector
  • Electrical definition:
Node
1
2
3
4
Function
Positive Power
Negative Power
/
Signal
CY-YZ-209 Pressure Sensor
  • Measuring medium: rocket propellant, nitro-gen, helium, etc.
  • Operating temperature: -10°C~60°C
  • Input voltage: 28V±5VDC
  • Range: 0~3.5MPa (customizable)
  • Output signal: 0.1~5V
  • Accuracy: 0.1% FS
  • Long-term stability: 0.1% FS
  • Temperature drift: ≤±1% FS/°C (5°C~60°C)
  • Pressure overload: 200% FS
  • Pressure interface: M14×1.5
  • Electrical interface: connectors
  • Electrical definition:
Node
1
2
3
Function
Positive Power
Negative Power
Output
CY-YZ-218 Temperature/Pressure Combination Sensor
  • Measuring medium: 15# aviation hydraulic oil
  • Operating temperature: -55°C~135°C
  • Input voltage: 10~28VDC
  • Pressure measuring range: 0~3.5MPa (gauge)
  • Temperature measuring range: -60°C~150°C
  • Pressure zero output: 0~0.03V
  • Full pressure output: 5V±0.03V
  • Pressure normal temperature error: ≤±0.5% FS
  • Pressure high and low temperature error: ≤±1.5% FS
  • Temperature zero output: 0~0.03V
  • Temperature full output: 5V±0.03V
  • Temperature measuring accuracy: ±1°C
  • Pressure overload: 200% FS
  • Pressure interface: M16×1
  • Electrical interface: direct outgoing cable
  • Electrical definition:
Lead
Red
White
Green
Blue
Gray
Function
Positive
Power Ground
Pressure Signal
Temperature Signal
Signal Ground
WSY-10 Environmental Sensor
  • Measuring medium: air
  • Input voltage: 18~36VDC
  • Temperature range: -40°C~60°C
  • Temperature accuracy: 0.5°C
  • Pressure range: 80~150kPa
  • Pressure accuracy: 0.5kPa
  • Moisture measurement range: 0~100% RH
  • Humidity accuracy: ±3% RH (10~50°C, 10~90% RH); ±8% RH (other temperatures)
  • Output signal: three-way RS422 signal output
  • Pressure overload: 150% FS
  • Pressure interface: M24×1
  • Electrical interface: direct outgoing cable
  • Electrical definition:
Node
1
2
3
4
Function
Positive Output
GND
5~12VDC
RS-422TX+
Node
5
6
7
8
Function
RS-422TX-
RS-422RX+
RS-422RX-
422 Signal
CDL-HE-01 Current Sensor
  • Measuring medium: electric current
  • Operating temperature: -45°C~125°C
  • Input voltage: 10~36VDC
  • Range: 0~300A (customizable)
  • Output signal: 2.2~7.2V (customizable)
  • Accuracy: ≤3% FS
  • Electrical interface: connectors
  • Electrical definition:
Node
1
2
3
4
Function
Positive Power
Negative Power
Negative Signal
Positive Signal
CR-YZ-100 Heat Flow Sensor
  • Measuring range: 0~3MW/m2
  • Operating temperature: -60°C~1100°C
  • Response time: 0.1s
  • Sensitivity: ≥63W/(m2·μv)
  • Output signal: DC voltage, full scale about 66.7mV
  • Accuracy: 3% FS
  • Output wire: high temperature quartz fiber wire, length 500mm
  • Thermal overload: 150% FS
  • Electrical interface: direct outgoing cable
  • Electrical definition:
Output
Red
Black
Function
Heat Flow Signal
Temperature Signal
TSA03-1 Monitoring Module
  • Measuring medium: oil, fuel, seawater, air, exhaust, etc.
  • Operating temperature: -45°C~200°C
  • Input voltage: 15VDC
  • Range: one-way 0~3MPa; six-way 0~150kPa (customizable)
  • Output signal: 0.5V±0.1V~3V±0.1V
  • Accuracy: 0.5% FS
  • Temperature drift: ≤±0.05% FS/°C
  • Pressure overload: 200% FS
  • Pressure interface: M16×1.5
TC-YL-02 Portable Pressure Testing Kit
  • Sensor temperature range: -55°C~125°C
  • Pressure output range: 20kPa~2.5MPa absolute pressure, -80kPa~2.5MPa gauge pressure
  • Number of sensor interfaces: 3 (low pressure: 1; high pressure: 2)
  • Comprehensive accuracy of pressure control: 0.1% FS
  • Sensor power supply output: 5~24V
  • Voltage measurement accuracy: 0.05%+2mV
  • Current measurement accuracy: 0.05%+2μV
  • Size: 520×400×220mm
  • Weight: ≤15.5kg
Automatic Testing System for Pressure Sensors
  • Pressure measuring range: 0~60MPa (customizable)
  • Pressure accuracy: 0.01% FS
  • Operating temperature: -55°C~150°C
  • Temperature stability: ±2°C
  • Sensor excitation: constant pressure/constant current
  • Signal measurement: 7-bit semi-precision digital multimeter
  • Supported conditioning chips: MAX1452, ZMD30105
  • Calibration calculation method: least square method, translation end base line method, best straight line method
  • Power supply : 380V/50Hz
  • Power: 8kW
  • Dimension: 4200×3500×2000mm